Picture
This photo shows the result of settling for a sub-standard installation by what was supposed to have been a certified pool electrician.  In 2011 I decided to replace the old pool timers and at the same time converted to a salt water system (which I don't regret!).  Not having the time to do it myself, I hired a contractor through one of the larger pool supply stores here in town.  He came out, worked for about 4-5 hours and left a jumbled arrangement of boxes attached to the exterior of the garage.  At the time, it was no big deal, but time and weather quickly took its toll and the weakness of the installation became apparent when two yeas later the boxes were literally falling off the wall!

The problems: 1) timer boxes for the pumps and salt cell secured to a high-relief stone wall with 1.5" common fasteners (not nearly long or large enough for the load), 2) boxes not lined up neatly and awkwardly positioned too far from the edge of the paved step, 3) main cut off switches not wired to the interior of the pool timer box, and 4) cables left loose and unsecure. 

Picture
I think most will agree, this picture shows a far better installation, even before I tied down all the cables!  To accomplish this, I removed both boxes and build a steel component rack out of shelving stock.  With the rack secured to the wall with masonry anchors, each box was rehung with stainless steel hardware.  All the wiring was re-routed into the boxes using more direct connections and fewer cables.  Also, the cut off switches were relocated into the base of the lower pump timer box (not shown in picture).



 
 
Picture
When a customer recently requested the construction of a cover for an above-ground pump, he asked that it be built to resemble a composting bin.  Aesthetically a composting bin on the edge of the property would make sense.  I got to work immediately and built a custom enclosure with room to spare so that pump maintenance could be performed.  Installation of the enclosure on the steeply sloped yard took some shovel work, but in all it fit well.  This product was designed and built with minimal input on the specs from the customer.  Just a general statement of what was required.
-Eric

 
 
Picture
This December I noticed a local advertisement in which a home owner was seeking assistance to a pair of problems he found bothersome.  The first was an upstairs shower faucet that was not producing hot water and the second was a pair of pool drains that have lost their protective covers.  I immediately recognized the complexity of the second issue and contacted him with a recommendation.

The next day we met and I had the opportunity to inspect the situation.  Hard water had caused a calcium build up in his shower valve.  I recommended an experienced plumber who could come and address the issue with a full complement of tools necessary to replace the rough in.  In my estimation, the calcium build up was beyond a second attempt at repair and the situation needed the extensive specialty work and warranty a licensed plumber could provide.  That second opinion cost him nothing but did help his decision making.

The pool drains were a different matter entirely.  The original installation did not use stainless steel screws to secure the drain covers.  In the intervening years these screws rusted away in place, and the Polaris skimmer eventually was able to knock loose the covers, causing a safety hazard to swimmers.  Knowing that he would not have an easy time finding a pool service company that can fix this problem (especially in 54 degree water), I offered to do the dive myself.  I'm a certified recreational diver so rounding up the tools was not difficult.  The solution called for removing/grinding down the rusted screws, re-drilling some holes and replacing the screws with stainless steel versions...in 6 ft of bone-chilling  water.  How would you have done it?

The point of this story is that I was able to complete the job safely and to the satisfaction of the customer.  He did not have to drain the pool nor wait until spring to fix the problem.  Good planning, some obsolete hand tools and a tolerance for cold water dives made all the difference.
-Eric